Skip to content

MeteringResponse

Upon receiving and processing a Metering message, the receiving implementation must reply with a MeteringResponse, indicating whether the update was handled successfully.

<MeteringResponse
  Metadata…
  ReferenceMessageID = UUID
  Result             = ("Accepted" | "Rejected")
  RejectionReason    = String (Only if Result = "Rejected")
/>
Metadata The metadata for this message. For details, see section metadata attributes.
ReferenceMessageID MessageID of the Metering message that has just been accepted or rejected.
Result Indication whether the order was accepted or rejected.
RejectionReason In case the metering was rejected, this attribute must contain a human-readable description of the reason.